The requirement for good level control of flotation machines is well established and documented. In this article we will focus on the more common level measurement options available in the market in the flotation plant today, including the pros and cons associated with each one.

All level control loops consist of essentially three main components:  the level measurement sensor, the level controller and the level control valve.  In order to achieve good level control each of the components need to work well.

eDART Slurry Valves (PTY) LTD  have been manufacturing  and supplying  a range of  level control dart valves specifically for  global flotation market for over 10 years.  Our customers include the largest OEMs, and engineering firms and mining houses that operate in this niche market space.

A well known expression amongst Control and Instrumentation engineers is   “the most reliable measurement will always be non-contact and have no moving parts.”

The reason for this is linked to the robustness and reliability of the instrument.   Any instrument that is in contact with the measured medium and has moving parts is going to be far more prone to failure, more so, if that medium happens to be slurry.

Unfortunately this is not always achievable and in this case we generally settle for as close to the ideal as is practically possible.

Level measurement of a flotation cell is not as straightforward as it first sounds.  By level we are actually meaning froth depth.   Of interest in a flotation cell is how deep is the froth above the slurry,   as this determines the grade of the resulting concentrate.   The typical range for a froth depth of a flotation cell is 600 mm from the top of the cell, the launder, down to the slurry interface.  Here we are actually trying to measure the depth of a   froth, or foam layer.  As the level we are interested in is covered in froth, measuring it is a lot more challenging. 

Measurement Techniques

All the measurement techniques share a few common requirements. The ability to transmit the measured level back to the control room reliability, often through a hostile environment, resist EMI and RFI, and update within an acceptable time frame.  The loop powered current signal which works on a range of 4 – 20 mA is still by far the most common way of transmitting a level signal to the control room.  It has proven itself as being reliable, stable and has the useful ability to indicate a wire break or fault.   As the current signal would then fall away to zero.

Modern digital bus technology is  gaining popularity due to the  minimising of  signal cables required, even more recently wireless transmitters are  being introduced ,which eliminate signal cables altogether.  Even though changes in level in the average flotation cell are relatively slow you still need to update the signal frequently.  For control, you always want your sample rate to be at least ten times faster than your loop update rate, and you need to refresh the level signal at worst once per second.

One of the oldest level measuring techniques is via a rotary potentiometer connected to a float arrangement.  The float at the slurry/froth interface is connected to the rotary potentiometer by a set of mechanical linkages not unlike a pantograph. This is a simple instrument, but it has been so unreliable that it is seldom used in modern plants.  The mechanical linkages become stiff and jammed with froth and eventually the instrument does not respond to the changes in level. These devices are maintenance intensive. 

In addition the conversion from the linear movement of the float to a rotary potentiometer introduces a non-linear error as well.   With all float systems, if a cross current exists in the flotation machine it will be necessary to install a stilling well around the float.  

An ultrasonic level measurement alone cannot be used as the froth absorbs the ultrasonic signals, likewise with infrared and radar.

Probably the most common, although not ideal, method of measuring level in a flotation cell is via a combination of an ultrasonic level transmitter and a target plate assembly.   This technique involves   connecting a “target plate” to a float and then measuring the changes in height of the target plate using an ultrasonic instrument.  

The ultrasonic transmitters are now a mature technology having been in the market for over 15 years and supplied by a number of world class instrumentation suppliers.  Generally they work well and are cost effective.

However, the problem with this technique is once again with the mechanical components that are in contact with the froth and slurry.  They suffer from coming into contact with the froth, causing them to stick or jam, and the slurry build-up changes the buoyancy of the float.  All resulting in increased maintenance and wear rates and decreased reliability.

Guided wave radar is a step closer to the ideal instrument in that it does not have any moving parts.  These instruments use a metal tube as the antennae, or wave guide, for the radar.  The wave guide is extended into the slurry interface, the radar signal traveling along the wave guide is reflected back off the slurry interface to be detected by the instrument.   The time the signal takes to return to the instrument is directly proportional to the level. 

A slurry build up on  the wave guide used to be a problem  for this technique instrument,  however the introduction  of  modern  instruments  that feature multiple frequency radar waves have virtually eliminated this problem.  Even so these units are not popular for the simple reason that they are costly, when compared to the alternatives. 

Understanding that flotation concentrators often have in excess of fifty flotation machines requiring level measurement, explains the customer’s sensitivity to cost per level point.  

Another approach, which is fairly common is based on the magnetoresistive principal.  Here a magnetic sensor within a sealed pipe moves in relation the slurry level in the flotation cell, up and down, a wire sensor.  The signal transmitted down the wire is reflected by the induced magnetic field in the wire sensor and therefore indicates the level in the flotation machine. 

This type of sensor is accurate and repeatable and it also has extremely fine resolution, in the order of 0.5 mm.   However as the magnetic sensor is coupled to a float on the slurry interface, it is susceptible to slurry build up as in all float systems. Despite this, it is now one of the more successful techniques seen in us in the market.

Conductance type level sensors can also be found in this market.  Here the sensors make use of the electrical conductivity to indicate the slurry level.  As the slurry level changes so does the conductance of the sensor.  Sometimes also referred to as resistivity type instruments as conductance is the reciprocal of resistance, or resistivity.  As the ore is never consistent, these sensors suffer from the fact that ore changes, changes in the conductivity of the water, or reagent changes in type and strength will result in a change of conductance measured, resulting in frequent re-calibration requirements.   More modern instruments include more than one measurement technique which has resulted in more reliable measurements.

There is a lot of exciting development work being done using this measurement principal.  These instruments have been developed to the extent where they can give an output signal of “froth density” over the length of the measured range and the froth/slurry interface as well as the froth height, other than the simple slurry interface point   Again, it is the sophisticated instruments that work fairly well, which come at a cost.

Theoretically, it is possible to use X-Ray to determine the slurry level interface however the costs and safety considerations make this an impractical option.   Personally, I have never seen such an instrument in use in flotation.
 
As  you can see there is  no shortage  of choice for flotation level measuring instruments out there  but as yet none of them meets the full requirements for the ideal instrument, “Non-contact and moving parts “, so the search continues….
Richard Rule Brief CV

Studied HND in Instrumentation and Control on an AECI bursary, completed in 1990.

Joined Outokumpu, specialist flotation and mineral processing equipment supplier in 1996, as Control and Instrumentation Engineer and Project Manager.

Started eDART Slurry Valves with Mike Sessions in 2005 to produce slurry control valves.

Left Outokumpu in 2009 as manager responsible for process upgrades, to join eDART Slurry Valves full time. 

2009   -  Present,  Director for  eDART Slurry Valves (Pty) LTD .

Edited by Creamer Media Reporter

Comments

Showroom

Aqs image
AQS Liquid Transfer

AxFlow AQS Liquid Transfer (Pty) Ltd is an Importer and Distributor of Pumps in Southern Africa

VISIT SHOWROOM 
Werner South Africa Pumps & Equipment (PTY) LTD
Werner South Africa Pumps & Equipment (PTY) LTD

For over 30 years, Werner South Africa Pumps & Equipment (PTY) LTD has been designing, manufacturing, supplying and maintaining specialist...

VISIT SHOWROOM 

Latest Multimedia

sponsored by

Photo of Martin Creamer
On-The-Air (26/04/2024)
Updated 6 hours ago By: Martin Creamer
Magazine cover image
Magazine round up | 26 April 2024
26th April 2024

Option 1 (equivalent of R125 a month):

Receive a weekly copy of Creamer Media's Engineering News & Mining Weekly magazine
(print copy for those in South Africa and e-magazine for those outside of South Africa)
Receive daily email newsletters
Access to full search results
Access archive of magazine back copies
Access to Projects in Progress
Access to ONE Research Report of your choice in PDF format

Option 2 (equivalent of R375 a month):

All benefits from Option 1
PLUS
Access to Creamer Media's Research Channel Africa for ALL Research Reports, in PDF format, on various industrial and mining sectors including Electricity; Water; Energy Transition; Hydrogen; Roads, Rail and Ports; Coal; Gold; Platinum; Battery Metals; etc.

Already a subscriber?

Forgotten your password?

MAGAZINE & ONLINE

SUBSCRIBE

RESEARCH CHANNEL AFRICA

SUBSCRIBE

CORPORATE PACKAGES

CLICK FOR A QUOTATION







sq:0.098 0.252s - 158pq - 2rq
Subscribe Now